All models vent with standard 4' or 6'diameter PVC plastic pipe. Super Duty units can be installed with Power Vent or Power Direct Vent configurations. LCD User Interface. The new LCD user interface is standard on all Super Duty models. It enables installers and service technicians to monitor key functions and components. Rheem Professional Classic Series Power Vent Water Heater Top Quality Brand Name Products Rheem Professional Classic Series Power Vent Water Heater Uses outside air for combustion offering longer venting options, and energy efficiency, it’s dependable, versatile and high preforming as well as maintenance free. Installation, operation, and service manual power vent storage type gas water heater models pvg/pvcg these instructions are intended as an aid to qualified service personnel for proper installation, adjustment and operation of this water heater. Read these instructions thoroughly before attempting installation or operation. This heat pump water heater is factory charged with an environmentally friendly, non-chlorinated refrigerant, R410A. This refrigerant has zero ozone depletion potential. Inspect Shipment Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be certain the power supply corresponds to the water.
All Brands > Rheem > Checkins > Repair
Most of the problems with a Rheem gas water heater will be related to the FVIR lockout. With most models your first step should be to press the TCO thermal reset button which is located on the front of the combustion door.
Clean the Intake
Rheem Power Vent Water Heater Service Manuals
The next step should be to clean the intake of the water heater. A clogged intake can cause the thermal button to trip. A shop vac with a custom extension or even compressed air can be used to clean the flame arrestor screen (intake). In order to access the intake you will usually need to remove the combustion door.
TRD Glass Vial
Rheem Water Heater Manuals Online
Rheem Power Vent Water Heater Service Manual Thermal Fuse
The above steps will not work for every type of Rheem water heater or for every situation. Many of the Rheem water heaters have a Vial that is located inside of the combustion chamber. If the vial has burst, you will need to wait for a new vial to be shipped. You should also clean out the combustion chamber and pilot assembly. If the pilot is yellow instead of blue there is too much corrosion on the pilot assembly.
Thermocouple or Gas Valve
Rheem Water Heater Manual Download
The next step in troubleshooting should be to test the thermocouple. When attempting to light the water, the flame will usually go out after releasing the control knob when the thermocouple has failed. If the flame continues to burn after releasing while in the PILOT position but shuts down when in the ON position the FVIR may have tripped the system. If the thermocouple shows a good reading you may need to replace the gas valve and FV sensor.